PENTACIS®
|
Isotope | Technetium (99mTc) |
Number of radiolabelled preparations | 5 |
Each vial contains : Calcium trisodium pentetate (DTPA Ca Na3) 9.10 mg Stannous chloride dihydrate Sodium chloride Under a nitrogen atmosphere |
9.10 mg |
Volume of pertechnetate 99mTc to use for reconstitution | 5 mL |
Radiochemical purity | > 95 % |
Storage | 4 hours from labelling with a maximum of 5 withdrawals per vial |
Activity per vial | 3.7 to 2000 MBq |
Indications / Posology |
1) Intravenous use : - Renal glomerular filtration1.8 to 3.7 MBq (plasma) - Renal glomerular filtration 37 to 370 MBq (scanning) - Brain scanning 185 to 740 MBq 2) Inhalation : - In nebuliser : 500 to 1000 MBq - In lung : 50 to 100 MBq 3) Oral use : Study of gastro-oesophageal reflux and gastric emptying : 10 to 20 MBq |
Stability of labelled product | 4h at 2 - 8°C with a maximum of 5 withdrawals per vial |
Time between injection and examination |
Optimal static renal imaging : 1 hour Renal sequential scanning : immediately Brain static images : 1 hour to several hours Dynamic recording : first minutes up to 120 minutes for gastroduodenal transit. |
Availability | From stock |